TECHNICAL DATA
Limit values:
- minimum revs 200 RPM
- maximum revs 20000 RPM
- minimum supply voltage 8 Volts
- maximum supply voltage 16 Volts
- max. supply voltage for 1 minute 35 Volts
- current draw 25 mAmp
- maximum continuous current for shift light output 1 Amp
Circuit is protected against reverse supply voltage (wrong connection).

Features:
- CDI charged from hi voltage charging coils (generator)
- store and load function for 2 ignition maps
- one input for magnetic pickup
- external switch for changing ignition map while riding
- shift light output
- quick shift (shift kill)
- tachometer output
- advance/retard whole ignition curve
- three stage rev limit (retard timing, reduced spark, spark off)
- signal delay compensation
- timing calculation for every 1 RPM change (1000, 1002, .. , 9805, 9806, ...)
- programmable power valve actuation
- store and load function for 5 PV curves
- programmable PV deviation
- programmable max close and max open positions
- self PV test on power-up
- PV error detecting (position sensor failure, servo motor failure)
- easy and fast programming on the field, via hand held programmer
- programming while machine running - you can immediately see effects
- monitoring of rev's, ignition and PV angle, via LCD(hand held programmer)
- fast processing for high accuracy - delays from 1us